Testo Saveris
Category: DATA LOGGER, TEMPERATURE, HUMIDITY
Model: Humidity, Pulse Event State, Temperature, Temperature Data Logger, Humidity Data Logger
Avaibility: AVAILABLE
Call For Price
Talk with one of our sales
Monday to Friday 8AM - 5PM WIB
021- 72791867
Testo Saveris
Category: DATA LOGGER, TEMPERATURE, HUMIDITY
Model: Humidity, Pulse Event State, Temperature, Temperature Data Logger, Humidity Data Logger
Avaibility: AVAILABLE
Call For Price
The measurement data monitoring system testo Saveris monitors temperature and humidity values without interruption in wide-ranging measurement sites. Wireless and Ethernet probes allow versatile applications:
• Monitoring and documentation in Production, Quality Assurance and R & D
• Monitoring of the storage climate of valuable inventory, medicaments and foods
• Monitoring of the food cold chain The Base is the heart of testo Saveris and can store 40,000
measurement values.
The large selection of wireless probes allows a practically unlimited versatility of application. The existing LAN structure can be used with the Ethernet probes. The Router improves wireless connection in unfavourable constructional situations. By connecting a Converter to an Ethernet socket, the signal from a wireless probe can be converted to an Ethernet signal.
Testo Saveris wireless probes
Probe versions with internal as well as external temperature and humidity sensors allow the adaptation to any application. The wireless probes are available optionally with or without display. The current measurement data, the battery status and the quality of the wireless connection are shown.
Testo Saveris Router
The use of a router can improve or extend the wireless connection in difficult constructional circumstances. Several routers in the testo Saveris system are of course possible. At the same time, the serial switching of up to 3 routers V 2.0 provides the highest level of flexibility regarding wireless range.
Testo Saveris Converter
By connecting a testo Saveris converter to an Ethernet socket, the signal from a wireless probe can be converted into an Ethernet signal. This combines the flexible installation of a wireless probe with the exploitation of the existing Ethernet even over long transmission distances.
Testo Saveris analog coupler
The two versions of the analog coupler (wireless/Ethernet) allow the integration of further measurement parameters into the testo Saveris monitoring system, by including all transmitters with standardized current/voltage interfaces, e.g. 4 to 20 mA or 0 to 10 V
Humidity and differential pressure
transmitters testo 6651/6681/6351/6381/6383 By integrating the humidity and differential pressure transmitters, measurement data monitoring parallel to the control is possible. This offers the solution for highest accuracy as well as for special applications (high humidity, trace humidity etc.) in compressed air, drying and air conditioning technology.
Testo Saveris Base
The base is the heart of testo Saveris, and can store 40,000 measurement values per measurement channel independently of a PC. This corresponds to a storage capacity of approximately a year at a measurement rate of 15 minutes. System data and alarms are visible via the Saveris base display.
Testo Saveris software
The testo Saveris software offers easy operation as well as an intuitive user interface. The Saveris software is available in three different versions: as a basic version SBE (Small Business Edition), as a PROF version (professional) with many additional options, or as a CFR version. The CFR software fulfils the 21 CFR Part 11 requirements of the FDA, and is thus validatable.
Testo Saveris Ethernet probes
In addition to the wireless probes, probes can be used which can be directly connected to the Ethernet. This means that an existing LAN structure can be used, allowing the data transfer from probe to base even over large distances.
testo Saveris Base
Memory |
40,000 values per channel (total max. 18,000,000 values) |
Dimensions |
225 x 150 x 49 mm |
Weight |
Approx. 1510 g |
Protection class |
IP42 |
Housing material |
Diecast zinc / plastic |
Radio frequency |
2,4 GHz |
Power supply (absolutely necessary) |
6.3 V DC mains unit; alternatively via 24 V AC/DC plug-in/screw terminals, power consumption 4 W |
Rech. batt.* |
Li-ion battery (for data back-up and for emergency SMS if power supply fails) |
Operating temperature |
+5 to +45 °C |
Storage temperature |
-25 to +60 °C |
Display |
graphical display, 4 control keys |
Interfaces |
USB, radio, Ethernet |
Connectable radio probe |
max. 15 probes can be directly connected via wireless interface, max. 150 total via wireless / Router / Converter / Ethernet / Extender, max. 450 channels |
Alarm relay |
max. 1 A, max. 30 W, max. 60/25 V DC/AC, NC or NO contact |
GSM module** |
850 / 900 / 1800 / 1900 MHz not valid for Japan and South Korea |
Set up |
Table base and wall bracket included |
Firmware version |
2.X |
*Wearing part
** According to R&TTE - EN 301 511 (900/1800)
Router and Converter |
Part no. |
Saveris Router V 1.0, 2.4 GHz, radio transmission medium | 0572 0159 |
Saveris Router V 2.0, 2.4 GHz, radio transmission medium | 0572 0259 |
Saveris-Converter V 1.0, 2.4 GHz, converts the radio transmission medium to Ethernet | 0572 0158 |
Saveris-Converter V 2.0, 2.4 GHz, converts the radio transmission medium to Ethernet | 0572 0258 |
Technical data |
Saveris router V 1.0 |
Saveris Router V 2.0 |
Saveris converter V 1.0 |
Saveris Converter V 2.0 |
Application |
|
|
|
|
Dimensions |
Approx. 85 x 100 x 38 mm |
|||
Weight |
Approx. 180 g |
Approx. 190 g |
||
Power supply |
6.3 V DC mains unit; alternatively via 24 V AC/DC plug- in/screw terminals, power consumption á 0.5 W |
6.3 V DC mains unit; alternatively via 24 V AC/DC plug-in/screw terminals, PoE, power consumption á 2 W |
||
Operating temperature |
-20 to +50 °C |
|||
Storage temperature |
-40 to +60 °C |
|||
Housing material |
Plastic |
|||
Protection class |
IP54 |
|||
Interfaces |
Radio |
Radio, Ethernet |
||
Connectable radio probe |
max. 5 |
max. 15 |
||
Router cascading |
no |
yes |
- |
- |
Wall bracket |
included |
Version without display | Part no. |
Saveris T1 Radio probe with internal NTC, radio frequency 2.4 GHz, without display | 0572 1250* |
Saveris T2 Radio probe with external probe connection and internal NTC, door contact, radio frequency 2.4 GHz, without display | 0572 1251* |
Saveris T3 2-channel radio probe with 2 external TC probe connections (choice of TC characteristics), radio frequency 2.4 GHz, without display | 0572 9252* |
Saveris Pt Radio probe with 1 external Pt100 probe connection, radio frequency 2.4 GHz, without display | 0572 7251* |
Version with display |
Part No |
Saveris T1 D Radio probe with internal NTC, radio frequency 2.4 GHz, with display | 0572 1260* |
Saveris T2 D Radio probe with external probe connection and internal NTC, radio frequency 2.4 GHz, with display | 0572 1261* |
Saveris T3 D 2-channel radio probe with 2 external TC probe connections (choice of TC characteristics), radio frequency 2.4 GHz, with display | 0572 9262* |
Saveris Pt D Radio probe with 1 external Pt100 probe connection, radio frequency 2.4 GHz, with display | 0572 7261* |
The alkali manganese batteries AA (0515 0414) are included in these ordering data (analog coupler excluded). Saveris probes are delivered with a calibration protocol of the factory adjustment data. Calibration certificates must be ordered separately.
Technical data |
Saveris T1 |
Saveris T2 |
Saveris T3 |
Saveris Pt |
|||||
Probe type |
NTC |
NTC |
– |
– |
|
||||
Measuring range |
-35 to +50 °C |
-35 to +50 °C |
– |
– |
|
||||
Accuracy |
±0.4 °C (-25 to +50 °C) ±0.8 °C (remaining range) |
±0.4 °C (-25 to +50 °C) ±0.8 °C (remaining range) |
– |
– |
|
||||
Resolution |
0.1 °C |
0.1 °C |
– |
– |
|
||||
Probe type |
– |
NTC |
TC type K TC type J |
Pt100 |
|
||||
Measuring range (Instrument) |
– |
-50 to +150 °C |
-195 to +1350 °C -100 to +750 °C TC type T TC type S -200 to +400 °C 0 to +1760 °C |
-200 to +600 °C |
|
||||
Accuracy (Instrument) |
– |
±0.2 °C (-25 to +70 °C) ±0.4 °C (remaining range) |
±0.5 °C or 0.5% of m.v. |
at +25 °C ±0.1 °C (0 to +60 °C) ±0.2 °C (-100 to +200 °C) ±0.5 °C (remaining range) |
|
||||
Resolution (Instrument) |
– |
0.1 °C |
0.1 °C/TC type S 1 °C |
0.01 °C |
|
||||
Connection |
– |
NTC via mini-DIN socket, door contact connection cable included in delivery (1.80 m) |
2 TCs via TC socket, max. difference in potential 2 V |
1 Pt100 via mini-DIN socket |
|||||
Dimensions (housing): |
80 x 85 x 38 mm |
||||||||
Weight |
Approx. 240 g |
||||||||
Battery life (Type: 4 AA batteries) |
Battery life at +25 °C, 3 years; for freezer applications, 3 years with L91 Photo lithium Energizer batteries |
||||||||
Housing material |
Plastic |
||||||||
Protection class |
IP68 |
IP54 |
IP68 |
||||||
Radio frequency |
2,4 GHz |
||||||||
Measuring rate |
Standard 15 min, 1 min to 24 h can be set |
||||||||
Memory |
6,000 measurement values per channel |
||||||||
Conformity with standards |
DIN EN 12830 |
– |
|||||||
Operating temperature |
-35 to +50 °C |
-20 to +50 °C |
|||||||
Storage temperature |
-40 to +55 °C (incl. batteries) |
||||||||
Display (optional) |
LCD, 2 lines; 7-segment with symbols |
||||||||
Transmission distance |
approx. 100 m w/o obstruction at frequency 2.4 GHz |
||||||||
Wall bracket |
included |
OTHER PRODUCT