CPH6400 -- Precision Hand-Held Pressure Indicator
Category: PRESSURE, CALIBRATORS
Model: Portable Calibrators, Portable Calibrator
Avaibility: OUT OF STOCK
Call For Price
Talk with one of our sales
Monday to Friday 8AM - 5PM WIB
021- 72791867
CPH6400 -- Precision Hand-Held Pressure Indicator
Category: PRESSURE, CALIBRATORS
Model: Portable Calibrators, Portable Calibrator
Avaibility: OUT OF STOCK
Call For Price
Features
A wide variety of reference pressure sensors, offering various measuring ranges of up to 6,000 bar (75,000 psi), are available to the operator, always ensuring a solution matched to the application. The individual sensors can be exchanged quickly and without tools (plug-and-play) and are automatically recognised by the digital indicator. Also, as an option, very accurate temperature measurement with a Pt100 temperature probe is possible. In addition, this instrument features a large, easily-read display with backlighting (on/off selectable), a durable case and simple, clear operation.
Functionality
In addition to mobile and high-precision pressure and temperature measurement, the CPH6400 also opens up other helpful applications e.g. recording of pressure and temperature curves (via the logger function), leak testing (via the pressure rate function) and peak value determination (via the Min./Max. function).
Software
The WIKA-Cal calibration software is available both for reading the logger data stored in the CPH6400 as well as for online calibrations in connection with a PC. Using this software, the calibration data is automatically transferred into a printable calibration certificate. Furthermore, WIKA-Cal also offers, over and above PC-supported calibration, the management of the calibration and instrument data in an SQL database.
Complete test and service cases
For maintenance and service applications, various case systems are available. These include service cases with/ without pressure generation, power supply unit/charger, connection adapter, etc.
Certified accuracy
For each reference pressure sensor and Pt100 temperature probe, the accuracy for the complete measuring chain is certified by a factory calibration certificate which accompanies the instrument. On request, a DKD/DAkkS calibration certificate will be provided for this instrument.
Sensor technology |
1 reference pressure sensor (exchangeable without tools) 1) |
|
|
|
|
|||||||
Measuring range |
|
|
|
|
|
|
|
|
|
|
|
|
Gauge pressure |
bar |
-1 ... |
0 |
|
-1 ... |
+0.6 |
-1 ... |
1.5 |
-1 ... |
3 |
-1 ... |
5 |
|
|
-1 ... |
9 |
|
-1 ... |
15 |
-1 ... |
24 |
-1 ... |
39 |
0 ... |
0.25 |
|
|
0 ... |
0.4 |
|
0 ... |
0.6 |
0 ... |
1 |
0 ... |
1.6 |
0 ... |
2.5 |
|
|
0 ... |
4 |
|
0 ... |
6 |
0 ... |
10 |
0 ... |
16 |
0 ... |
25 |
|
|
0 ... |
40 |
|
0 ... |
60 |
0 ... |
100 |
0 ... |
160 |
0 ... |
250 |
|
|
0 ... |
400 |
|
0 ... |
600 |
0 ... |
700 |
0 ... |
1,000 |
|
|
|
psi |
-15 ... |
0 |
|
-15 ... |
+15 |
-15 ... |
40 |
-15 ... |
70 |
-15 ... |
130 |
|
|
0 ... |
5 |
|
0 ... |
10 |
0 ... |
15 |
0 ... |
20 |
0 ... |
25 |
|
|
0 ... |
30 |
|
0 ... |
50 |
0 ... |
60 |
0 ... |
75 |
0 ... |
100 |
|
|
0 ... |
150 |
|
0 ... |
200 |
0 ... |
250 |
0 ... |
300 |
0 ... |
350 |
|
|
0 ... |
400 |
|
0 ... |
500 |
0 ... |
600 |
0 ... |
700 |
0 ... |
750 |
|
|
0 ... |
1,000 |
|
0 ... |
1,450 |
0 ... |
1,500 |
0 ... |
2,000 |
0 ... |
3,000 |
|
|
0 ... |
4,000 |
|
0 ... |
5,000 |
0 ... |
6,000 |
0 ... |
7,500 |
0 ... |
10,000 |
|
|
0 ... |
14,500 |
|
|
|
|
|
|
|
|
|
Accuracy of the measuring chain 2) |
0.025 % FS 3) |
|
|
|
|
|
|
|
|
|
|
|
Gauge pressure |
bar |
0 ... |
1,600 |
|
0 ... |
2,000 |
0 ... |
2,500 |
0 ... |
3,000 |
0 ... |
4,000 |
|
|
0 ... |
5,000 |
|
0 ... |
6,000 |
|
|
|
|
|
|
|
psi |
0 ... |
15,000 |
0 ... |
20,000 |
0 ... |
25,000 |
0 ... |
30,000 |
0 ... |
40,000 |
|
Accuracy of the measuring chain 2) |
0.1 % FS 3) |
0 ... |
50,000 |
0 ... |
60,000 |
0 ... |
75,000 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
Absolute pressure |
bar abs. |
-0.8 |
... 1.2 |
0 ... |
0.25 |
0 ... |
0.4 |
0 ... |
0.6 |
0 ... |
1 |
|
|
|
0 ... |
1.6 |
|
0 ... |
2.5 |
0 ... |
4 |
0 ... |
6 |
0 ... |
10 |
|
|
0 ... |
16 |
|
0 ... |
25 |
|
|
|
|
|
|
|
psi abs. |
0 ... |
5 |
|
0 ... |
10 |
0 ... |
15 |
0 ... |
20 |
0 ... |
30 |
|
|
0 ... |
50 |
|
0 ... |
60 |
0 ... |
100 |
0 ... |
150 |
0 ... |
300 |
Accuracy of the measuring chain 2) |
0.025 % FS 3) |
|
|
|
|
|
|
|
|
|
|
|
Overpressure limit |
3 times; < 25> |
|
|
|
3 times; < 360> |
? 8,700 psi |
|
|
||||
(depending on measuring range) |
2 times; > 25 bar ... ? 600 bar |
|
|
2 times; > 360 psi |
|
|
||||||
|
1.5 times; > 600 bar ... |
? 2,500 bar |
1.5 times; > 8,700 psi ... ? 36,260 psi |
|
||||||||
|
1.2 times; > 2,500 bar |
|
|
|
1.2 times; > 36,260 psi |
|
|
|||||
Pressure types |
Gauge pressure, {absolute pressure from 0 ... |
25 bar abs. (0 ... 360 psi abs.) and vacuum from |
||||||||||
|
-1 ... +39 bar (-14.5 ... |
566 psi)} |
|
|
|
|
|
|
|
|||
Sensor compatibility |
Compatible with model CPT6400 reference pressure sensors |
|
|
|
|
OTHER PRODUCT